石俊杰
摘要:心電圖機(jī)計(jì)量檢定過(guò)程中可能會(huì)受到不合理因素干擾,這會(huì)造成心電圖機(jī)計(jì)量檢定出現(xiàn)問(wèn)題,心電圖機(jī)的作用和運(yùn)行效果會(huì)受到很大影響。論文對(duì)心電圖機(jī)計(jì)量檢定予以研究,了解心電圖機(jī)計(jì)量檢定的現(xiàn)實(shí)意義和實(shí)施要求,根據(jù)心電圖機(jī)計(jì)量檢定問(wèn)題表現(xiàn)確定相關(guān)優(yōu)化措施,使得心電圖機(jī)計(jì)量檢定過(guò)程中各項(xiàng)問(wèn)題可以得到全面處理,確保心電圖機(jī)計(jì)量檢定水平和病人心臟組織診斷力度有所提升。
關(guān)鍵詞:心電圖機(jī) 計(jì)量檢定 問(wèn)題 優(yōu)化措施
Problems and Optimization Measures in Metrological Verification of Electrocardiograph
Shi Junjie
( Public Inspection and Testing Center of Yichuan County )
Abstract: Electrocardiogram machine metrological verification process may be affected by unreasonable factors, which will also cause electrocardiogram machine metrological verification problems, the role and operation effect of electrocardiogram machine will also be greatly affected. This paper will study the electrocardiogram machine metrological verification, understand the practical significance of electrocardiogram machine metrological verification and implementation requirements, and according to the electrocardiogram machine metrological verification problems to determine the relevant optimization measures. The problems in the process of electrocardiogram machine metrological verification can be comprehensively dealt with to ensure that electrocardiogram machine metrological verification level and patient heart tissue diagnosis strength has been improved.
Key words: electrocardiograph, metrological verification, problem, optimization measures
0 引言
對(duì)心臟組織進(jìn)行診斷和健康檢測(cè)時(shí)需要強(qiáng)化心電圖機(jī)在其中的應(yīng)用力度,減少病人心臟組織檢測(cè)診斷過(guò)程中產(chǎn)生的創(chuàng)傷,降低病人心臟組織檢測(cè)診斷難度,并在了解病人心臟問(wèn)題表現(xiàn)情況的同時(shí)確定關(guān)聯(lián)有效的臨床診斷方案。為提升心電圖機(jī)精準(zhǔn)性,也應(yīng)從心電圖機(jī)運(yùn)行狀況和實(shí)際作用角度出發(fā)確定計(jì)量檢定方案,并通過(guò)計(jì)量檢定對(duì)心電圖機(jī)運(yùn)行過(guò)程中可能出現(xiàn)的問(wèn)題進(jìn)行綜合處理。
1 心電圖機(jī)計(jì)量檢定的現(xiàn)實(shí)意義
從心電圖機(jī)計(jì)量檢定入手進(jìn)行研究分析,明確該項(xiàng)工作的現(xiàn)實(shí)意義主要表現(xiàn)在以下幾個(gè)方面:第一,盡管心電圖機(jī)在病人心臟組織活動(dòng)診斷中有重要作用,但是不可否認(rèn)心電圖機(jī)在長(zhǎng)時(shí)間運(yùn)行使用過(guò)程中也會(huì)出現(xiàn)一些問(wèn)題,這就應(yīng)根據(jù)心電圖機(jī)實(shí)際運(yùn)行狀況以及相關(guān)要求進(jìn)行有效的計(jì)量檢定,通過(guò)心電圖機(jī)計(jì)量檢定做好相關(guān)參數(shù)信息歸納收集工作,并利用準(zhǔn)確信息對(duì)心電圖機(jī)實(shí)際運(yùn)行過(guò)程中可能出現(xiàn)的各項(xiàng)問(wèn)題進(jìn)行有效處理。第二,按照具體要求針對(duì)心電圖機(jī)開(kāi)展有效的計(jì)量檢定還能實(shí)現(xiàn)相關(guān)裝置穩(wěn)定運(yùn)行的目標(biāo),使得相關(guān)裝置在臨床診斷中的作用有所提升。通過(guò)計(jì)量檢定也能對(duì)心電圖機(jī)參數(shù)信息變化情況以及電磁波表現(xiàn)情況做好相應(yīng)診斷處理工作,確保心電圖機(jī)運(yùn)行使用過(guò)程中出現(xiàn)的電磁波干擾問(wèn)題進(jìn)行全面處理,以此發(fā)揮心電圖機(jī)的臨床診斷價(jià)值。第三,通過(guò)有效的計(jì)量檢定也能對(duì)心電圖機(jī)實(shí)際運(yùn)行過(guò)程中產(chǎn)生的數(shù)據(jù)信息進(jìn)行精準(zhǔn)地歸納整理,按照各項(xiàng)數(shù)據(jù)信息確定心電圖機(jī)運(yùn)行模式,或者按照病人年齡狀況和心臟疾病表現(xiàn)情況確定合理參數(shù)信息,并在規(guī)劃調(diào)整相關(guān)參數(shù)信息的同時(shí)將心電圖機(jī)計(jì)量檢定的實(shí)際作用表現(xiàn)出來(lái)。而且通過(guò)計(jì)量檢定還能對(duì)心電圖機(jī)運(yùn)行參數(shù)規(guī)劃進(jìn)行綜合調(diào)整,維持心電圖機(jī)運(yùn)行參數(shù)準(zhǔn)確性,加強(qiáng)故障問(wèn)題實(shí)際監(jiān)管力度,擴(kuò)展心電圖機(jī)在臨床診斷中的應(yīng)用范圍。通過(guò)計(jì)量檢定也可以對(duì)心電圖機(jī)運(yùn)行的突發(fā)情況進(jìn)行有效處理,維持心電圖機(jī)運(yùn)行的連貫性和可靠性,為醫(yī)護(hù)人員提供有參考價(jià)值的心電圖信息。
2 心電圖機(jī)計(jì)量檢定的實(shí)施要求
2.1 檢定前期觀察
對(duì)心電圖機(jī)進(jìn)行計(jì)量檢定前需要對(duì)相關(guān)裝置的外形進(jìn)行有效觀察,并按照觀察結(jié)果和實(shí)際運(yùn)行參數(shù)確定計(jì)量檢定方案。同時(shí)按照計(jì)量檢定安全管控要求對(duì)電源插頭和電源線(xiàn)進(jìn)行有效檢查,對(duì)電源插頭和電源線(xiàn)存在的故障問(wèn)題進(jìn)行綜合處理。在心電圖機(jī)計(jì)量檢定前期觀察時(shí)也需要做好相應(yīng)記錄工作,保證各項(xiàng)基礎(chǔ)信息的準(zhǔn)確性,在準(zhǔn)確信息支持下調(diào)整心電圖機(jī)計(jì)量檢定方案,使得心電圖機(jī)計(jì)量檢定連貫性和現(xiàn)實(shí)運(yùn)行效果得到有效保障。
2.2 阻尼參數(shù)調(diào)整
正確合理的阻尼值和相關(guān)參數(shù)信息可以保障心電圖機(jī)穩(wěn)定持續(xù)的輸出效果和矩形波管控力度,這對(duì)于推進(jìn)心電圖機(jī)計(jì)量檢定良性開(kāi)展至關(guān)重要。因此,在心電圖機(jī)計(jì)量檢定過(guò)程中必須按照檢定要求對(duì)裝置運(yùn)行參數(shù)和阻尼補(bǔ)償值進(jìn)行有效調(diào)整,對(duì)心電圖機(jī)實(shí)際運(yùn)行過(guò)程中可能出現(xiàn)的問(wèn)題和面臨的影響因素進(jìn)行綜合處理。保證阻尼參數(shù)設(shè)置在心電圖機(jī)計(jì)量檢定中的作用,確保心電圖機(jī)計(jì)量檢定可以在合理參數(shù)信息支持下良性開(kāi)展。
2.3 電源綜合檢查
心電圖機(jī)計(jì)量檢定可能會(huì)因?yàn)橹绷麟娫春徒涣麟娫匆?guī)劃布置不夠合理而出現(xiàn)問(wèn)題,這就需要根據(jù)心電圖機(jī)出現(xiàn)的問(wèn)題進(jìn)行有效檢查,并在保證心電圖機(jī)直流電源和交流電源穩(wěn)定性的同時(shí)實(shí)現(xiàn)電壓、電流穩(wěn)定輸出的目標(biāo)??刂菩碾妶D機(jī)計(jì)量檢定過(guò)程中因?yàn)殡妷汉碗娏骱龈吆龅投霈F(xiàn)敏感元器件被擊穿的問(wèn)題,保證心電圖機(jī)計(jì)量檢定電壓和電流綜合控制效果,有效推進(jìn)心電圖機(jī)計(jì)量檢定安全穩(wěn)定開(kāi)展,彰顯電源綜合檢查在心電圖機(jī)計(jì)量檢定中的作用效果。
2.4 附件屏蔽保護(hù)
心電圖機(jī)計(jì)量檢定過(guò)程中可能會(huì)產(chǎn)生一系列電磁波干擾,這就需要保證導(dǎo)聯(lián)線(xiàn)布置位置的合理性和實(shí)際管理效果。避免心電圖機(jī)導(dǎo)聯(lián)線(xiàn)直接接觸電源、電線(xiàn)和墻線(xiàn),為心電圖機(jī)導(dǎo)聯(lián)線(xiàn)和相關(guān)附件提供有效保護(hù),屏蔽電磁波對(duì)心電圖機(jī)計(jì)量檢定產(chǎn)生的負(fù)面影響。當(dāng)然還需要對(duì)心電圖機(jī)計(jì)量檢定中出現(xiàn)的導(dǎo)聯(lián)線(xiàn)交叉和折疊問(wèn)題進(jìn)行有效處理,強(qiáng)化心電圖機(jī)計(jì)量檢定電磁波干擾問(wèn)題防控力度,滿(mǎn)足心電圖機(jī)計(jì)量檢定對(duì)導(dǎo)聯(lián)線(xiàn)以及周邊附件提出的屏蔽保護(hù)要求。
3 心電圖機(jī)計(jì)量檢定存在的問(wèn)題
3.1 整機(jī)不工作
心電圖機(jī)計(jì)量檢定過(guò)程中可能會(huì)因?yàn)楦黜?xiàng)不合理因素干擾而出現(xiàn)整機(jī)不工作的現(xiàn)象,影響心電圖機(jī)的運(yùn)行效果和診斷作用。心電圖機(jī)整機(jī)不工作表現(xiàn)在無(wú)任何反應(yīng)和指示燈異常這兩方面上,這應(yīng)當(dāng)根據(jù)心電圖機(jī)實(shí)際反映狀況和故障問(wèn)題進(jìn)行有效分析,了解心電圖機(jī)整機(jī)不工作現(xiàn)象的誘因,并對(duì)心電圖機(jī)計(jì)量檢定面臨的阻礙進(jìn)行有效處理。同時(shí)心電圖機(jī)無(wú)正常反應(yīng)和指示燈異常均會(huì)導(dǎo)致計(jì)量檢定工作遇到阻礙,計(jì)量檢定程序和具體工作也會(huì)出現(xiàn)停滯不前和現(xiàn)實(shí)作用下降等問(wèn)題,這就會(huì)影響心電圖機(jī)運(yùn)行效果和計(jì)量檢定的全面性,心電圖機(jī)在病人心臟組織診斷和臨床治療方案規(guī)劃中的作用效果難以彰顯。
3.2 矩形波異常
心電圖機(jī)在定標(biāo)電壓環(huán)境下進(jìn)行計(jì)量檢定可能會(huì)出現(xiàn)矩形波不夠標(biāo)準(zhǔn)合理的情況,這也會(huì)對(duì)實(shí)際檢定工作帶來(lái)嚴(yán)重的影響,加大心電圖機(jī)計(jì)量檢定出現(xiàn)各項(xiàng)問(wèn)題的可能性,心電圖機(jī)計(jì)量檢定與裝置現(xiàn)實(shí)運(yùn)行管理控制要求之間存在較大差距。而心電圖機(jī)定標(biāo)電壓環(huán)境下出現(xiàn)的矩形波異常問(wèn)題主要有波形振幅過(guò)大無(wú)法調(diào)回正常值、波形無(wú)規(guī)律振蕩及忽大忽小上下震動(dòng)、心電圖機(jī)定標(biāo)電壓上有缺口這三種故障問(wèn)題。加上心電圖機(jī)波形變動(dòng)情況與病人心臟跳動(dòng)規(guī)律之間存在緊密聯(lián)系,一旦出現(xiàn)異常情況必然會(huì)導(dǎo)致病人心臟組織活動(dòng)檢測(cè)結(jié)果與正常情況之間存在較大偏差,醫(yī)師對(duì)病人的診斷和實(shí)際治療工作開(kāi)展效果也會(huì)受到影響。
3.3 幅頻特性問(wèn)題
對(duì)心電圖機(jī)的運(yùn)行原理進(jìn)行分析,明確心電圖機(jī)的信號(hào)輸出幅度與信號(hào)接收頻率是一一對(duì)應(yīng)的,這就需要保證心電圖機(jī)各項(xiàng)信號(hào)表現(xiàn)的準(zhǔn)確性和統(tǒng)一協(xié)調(diào)配合效果,方便相關(guān)人員按照計(jì)量檢定結(jié)果以及各項(xiàng)信息對(duì)現(xiàn)存的問(wèn)題進(jìn)行有效校正。而受不合理信息和應(yīng)用環(huán)境的影響也會(huì)造成心電圖機(jī)計(jì)量檢定過(guò)程中幅頻特性問(wèn)題越來(lái)越嚴(yán)重,心電圖機(jī)信號(hào)輸出幅度和信號(hào)接收頻率之間的關(guān)聯(lián)性和協(xié)調(diào)統(tǒng)一效果也會(huì)受到很大影響。如果不能有效處理心電圖機(jī)計(jì)量檢定中各項(xiàng)問(wèn)題,就會(huì)造成心電圖機(jī)計(jì)量檢定和實(shí)際運(yùn)行頻率波形幅度超出誤差允許范圍,心電圖機(jī)計(jì)量檢定結(jié)果準(zhǔn)確性和實(shí)際運(yùn)行水平大幅度下降。
3.4 噪聲問(wèn)題
心電圖機(jī)在非正常工作狀態(tài)下可能會(huì)因?yàn)橥饨缫蛩馗蓴_而產(chǎn)生波形振動(dòng)問(wèn)題,形成的波動(dòng)信號(hào)會(huì)影響心電圖機(jī)計(jì)量檢定效果,現(xiàn)存問(wèn)題實(shí)際處理水平也會(huì)受到不合理因素的干擾。加上心電圖機(jī)計(jì)量檢定往往處于開(kāi)放環(huán)境下,這就會(huì)造成心電圖機(jī)在運(yùn)行和計(jì)量檢定過(guò)程中產(chǎn)生內(nèi)部噪聲和外部噪聲問(wèn)題,加大心電圖機(jī)計(jì)量檢定出現(xiàn)各項(xiàng)故障問(wèn)題的可能性,心電圖機(jī)出圖情況和相關(guān)診斷信息的準(zhǔn)確性下降,心電圖機(jī)計(jì)量檢定以及實(shí)際應(yīng)用運(yùn)行過(guò)程中各項(xiàng)誤差問(wèn)題不能得到有效調(diào)整。
4 心電圖機(jī)計(jì)量檢定的優(yōu)化措施
4.1 整機(jī)不工作優(yōu)化措施
對(duì)于心電圖機(jī)整機(jī)不工作現(xiàn)象來(lái)說(shuō),如果心電圖機(jī)指示燈不亮,說(shuō)明心電圖機(jī)電路沒(méi)有連接上。這就需要在心電圖機(jī)計(jì)量檢定過(guò)程中進(jìn)行供電電源檢查,如果心電圖機(jī)供電電源出現(xiàn)故障,就需要按照心電圖機(jī)供電電源故障點(diǎn)確定適當(dāng)維修方案,并及時(shí)更換心電圖機(jī)電源。而對(duì)于心電圖機(jī)計(jì)量檢定過(guò)程中出現(xiàn)的非電源故障來(lái)說(shuō),就需要根據(jù)心電圖機(jī)運(yùn)行狀況和整機(jī)不工作問(wèn)題表現(xiàn)對(duì)保護(hù)電熔進(jìn)行有效排除,如果心電圖機(jī)在計(jì)量檢定和運(yùn)行過(guò)程中出現(xiàn)電源線(xiàn)熔斷或者缺失等問(wèn)題,就應(yīng)及時(shí)更換調(diào)整心電圖機(jī)電路線(xiàn)。同時(shí)按照合理要求對(duì)心電圖機(jī)計(jì)量檢定出現(xiàn)的指示燈不亮現(xiàn)象進(jìn)行變壓器綜合檢測(cè)工作,針對(duì)性維修線(xiàn)路故障損壞問(wèn)題。分別有效地對(duì)心電圖機(jī)直流和交流這兩種供電系統(tǒng)的電路情況進(jìn)行檢測(cè),按照實(shí)際檢測(cè)結(jié)果對(duì)心電圖機(jī)電路進(jìn)行有效處理。保障心電圖機(jī)計(jì)量檢定電路暢通。如果心電圖機(jī)在指示燈亮的狀況下出現(xiàn)整機(jī)不工作問(wèn)題,需要先查看心電圖機(jī)電路整流管,按照檢查結(jié)果做好具體維修和更換處理,排除心電圖機(jī)計(jì)量檢定中整機(jī)不工作故障問(wèn)題,保障心電圖機(jī)整機(jī)不工作問(wèn)題處理效果和計(jì)量檢定優(yōu)化力度。
4.2 矩形波異常優(yōu)化措施
在定標(biāo)電壓狀態(tài)下進(jìn)行心電圖機(jī)計(jì)量檢定時(shí)可能會(huì)出現(xiàn)矩形波異常問(wèn)題,這就需要根據(jù)心電圖機(jī)計(jì)量檢定中矩形波異常問(wèn)題進(jìn)行有效處理,控制矩形波異常問(wèn)題對(duì)心電圖機(jī)計(jì)量檢定效果和實(shí)際運(yùn)行穩(wěn)定性產(chǎn)生不良影響。對(duì)心電圖機(jī)計(jì)量檢定中矩形波異常問(wèn)題進(jìn)行優(yōu)化處理時(shí),需要對(duì)矩形波異常表現(xiàn)以及幅值大小情況進(jìn)行有效分析,并按照心電圖機(jī)計(jì)量檢定情況和實(shí)際應(yīng)用要求對(duì)其中盤(pán)香彈簧進(jìn)行有效調(diào)整,保證心電圖機(jī)盤(pán)香彈簧運(yùn)行效果和現(xiàn)實(shí)作用,從而推進(jìn)心電圖機(jī)計(jì)量檢定順利開(kāi)展。而且心電圖機(jī)接觸不良也會(huì)導(dǎo)致運(yùn)行使用過(guò)程中出現(xiàn)矩形波忽大忽小的故障問(wèn)題。對(duì)這一故障問(wèn)題進(jìn)行優(yōu)化處理時(shí)需要對(duì)心電圖機(jī)中固定螺絲振動(dòng)情況和安裝固定缺陷進(jìn)行有效調(diào)整。對(duì)心電圖機(jī)各部位螺栓進(jìn)行固定處理,保證心電圖機(jī)計(jì)量檢定力度和運(yùn)行使用過(guò)程中矩形波異?,F(xiàn)象進(jìn)行有效處理。對(duì)于心電圖機(jī)定標(biāo)電壓上缺口問(wèn)題來(lái)說(shuō),應(yīng)按照心電圖機(jī)運(yùn)行使用情況對(duì)定標(biāo)電壓進(jìn)行穩(wěn)定化處理,或者按照計(jì)量檢定結(jié)果和相關(guān)信息對(duì)心電圖機(jī)接觸開(kāi)關(guān)進(jìn)行有效更換,從而提升心電圖機(jī)計(jì)量檢定水平和實(shí)際運(yùn)行效果,確保矩形波異?,F(xiàn)象綜合處理水平可以滿(mǎn)足心電圖機(jī)良性運(yùn)行要求。
4.3 幅頻特性問(wèn)題優(yōu)化措施
由于進(jìn)行心電圖機(jī)計(jì)量檢定時(shí)可能會(huì)因?yàn)楦黜?xiàng)不合理因素干擾而出現(xiàn)幅頻特性問(wèn)題,進(jìn)而影響心電圖機(jī)運(yùn)行的穩(wěn)定性和相關(guān)參數(shù)信息的準(zhǔn)確性。這就需要根據(jù)心電圖機(jī)運(yùn)行過(guò)程中表現(xiàn)出來(lái)的參數(shù)信息對(duì)計(jì)量檢定中出現(xiàn)的幅頻特性問(wèn)題進(jìn)行有效處理,盡量在關(guān)閉全部濾波的狀態(tài)下進(jìn)行心電圖機(jī)檢定,也就是說(shuō)工頻濾波器設(shè)置為關(guān)閉,基線(xiàn)漂移濾波器設(shè)置為關(guān)閉或最小值,肌電濾波器和低通濾波器設(shè)置為關(guān)閉或最大值,保持檢定環(huán)境免受外部電磁干擾,做好心電圖機(jī)和檢定儀的接地工作,保證心電圖機(jī)幅頻穩(wěn)定性,使得心電圖機(jī)幅頻參數(shù)和運(yùn)行狀況符合計(jì)量檢定實(shí)際開(kāi)展要求。病情嚴(yán)重程度不同的病人對(duì)于心臟組織活動(dòng)診斷的要求存在一定差異,這就需要按照各項(xiàng)差異表現(xiàn)適當(dāng)調(diào)整心電圖機(jī)各種狀況下的振動(dòng)幅頻。加上心電圖機(jī)在運(yùn)行過(guò)程中輸入的信號(hào)不同也會(huì)造成裝置運(yùn)行信號(hào)和頻率發(fā)生變化,根據(jù)各項(xiàng)差異表現(xiàn)對(duì)心電圖機(jī)計(jì)量檢定過(guò)程中幅頻特性問(wèn)題進(jìn)行有效處理,保證各項(xiàng)優(yōu)化措施的合理性,確保心電圖機(jī)表示出的心電圖峰與峰之間距離達(dá)到穩(wěn)定合理狀態(tài),方便心電圖機(jī)操作人員和醫(yī)護(hù)人員更加直觀準(zhǔn)確的判斷病人心臟組織活動(dòng)狀況和病情表現(xiàn)。逐步提升心電圖機(jī)計(jì)量檢定效果,使得心電圖機(jī)計(jì)量檢定現(xiàn)存問(wèn)題得到全面處理。
4.4 噪聲問(wèn)題優(yōu)化措施
心電圖機(jī)計(jì)量檢定和實(shí)際使用過(guò)程中可能會(huì)因?yàn)榱悴考\(yùn)行不夠合理而出現(xiàn)噪聲問(wèn)題,這就影響心電圖機(jī)計(jì)量檢定效果和實(shí)際運(yùn)行狀況,噪聲問(wèn)題也會(huì)影響醫(yī)護(hù)人員對(duì)病人內(nèi)臟組織活動(dòng)狀況診斷的有效性和全面性,使心電圖機(jī)在病人綜合診斷中的作用效果持續(xù)下降。心電圖機(jī)計(jì)量檢定中的噪聲問(wèn)題主要表現(xiàn)在內(nèi)部噪聲和外部噪聲這兩部分,這就需要根據(jù)這兩種噪聲問(wèn)題實(shí)際表現(xiàn)確定合理優(yōu)化調(diào)整方案,嚴(yán)防心電圖機(jī)在接收信號(hào)過(guò)程中因?yàn)槊舾性a(chǎn)生的振動(dòng)、電磁波和聲波等干擾而出現(xiàn)噪聲問(wèn)題。當(dāng)然還需要在心電圖機(jī)計(jì)量檢定過(guò)程中對(duì)相關(guān)裝置進(jìn)行有效接地處理,并對(duì)心電圖機(jī)導(dǎo)聯(lián)線(xiàn)系統(tǒng)進(jìn)行屏蔽保護(hù),降低心電圖機(jī)運(yùn)行噪聲,從而滿(mǎn)足心電圖機(jī)計(jì)量檢定以及相關(guān)工作現(xiàn)實(shí)開(kāi)展要求。使得心電圖機(jī)噪聲問(wèn)題優(yōu)化處理達(dá)到檢定標(biāo)準(zhǔn)誤差控制范圍,使得心電圖機(jī)運(yùn)行過(guò)程中誤差問(wèn)題進(jìn)行有效調(diào)整,使得心電圖機(jī)運(yùn)行穩(wěn)定性和噪聲管控力度有所提高,滿(mǎn)足病人心臟組織活動(dòng)診斷和相關(guān)信息收集要求,發(fā)揮心電圖機(jī)在病人實(shí)際診斷中的作用效果。
5 結(jié)語(yǔ)
為保證心電圖機(jī)運(yùn)行效果和實(shí)際作用,就需要加強(qiáng)心電圖機(jī)計(jì)量檢定力度。同時(shí)對(duì)心電圖機(jī)計(jì)量檢定過(guò)程中可能出現(xiàn)的問(wèn)題進(jìn)行優(yōu)化處理,將心電圖機(jī)計(jì)量檢定水平提升到一定高度,借此彰顯心電圖機(jī)在病人心臟組織活動(dòng)診斷中的作用效果。同時(shí)保證心電圖機(jī)計(jì)量檢定的優(yōu)化措施的完善性和合理性,針對(duì)性處理心電圖機(jī)計(jì)量檢定中各項(xiàng)問(wèn)題,確保心電圖機(jī)處于一個(gè)正常穩(wěn)定的工作狀態(tài)。
參考文獻(xiàn)
[1] 植維堅(jiān).數(shù)字心電圖機(jī)內(nèi)定標(biāo)電壓測(cè)量不確定度的評(píng)定[J].企業(yè)科技與發(fā)展,2019(6):138-140.
[2] 陳國(guó)東,項(xiàng)迪,蘇榮.心電圖機(jī)計(jì)量檢定時(shí)應(yīng)掌握的基本知識(shí)[J].中國(guó)計(jì)量,2019(8):123.
[3] 范培蕾,馮金玲,王曉陽(yáng),等.數(shù)字心電圖機(jī)計(jì)量比對(duì)結(jié)果分析研究[J].計(jì)量技術(shù),2019(12):53-56.
[4] 王軼,田欣欣,曹崢.數(shù)字心電圖機(jī)檢定中常見(jiàn)問(wèn)題探討[J].中國(guó)計(jì)量,2020(1):123.
[5] 周伶俐.數(shù)字心電圖機(jī)內(nèi)部噪聲電平檢定中外部干擾信號(hào)的排除[J].中國(guó)計(jì)量,2021(2):125-126.
中國(guó)質(zhì)量與標(biāo)準(zhǔn)導(dǎo)報(bào)2022年2期