李剛明
[中圖分類號] TU113.668;TU85
[文獻標(biāo)志碼]A
[文章編號]2095-6487 (2021) 02-0087-02
This Paper Analyzes the Application oflntelligent Fire Emergency
Lighting System in the Electrical Design of Civil Buildings
Li Gang-ming
[ Abstract] Tlus paper describes the composition and characteristics ofintelligent fire emergency lighting system, and then discusses the systemdesign and application methods, Combined with the scale, nature and function of civil buildings, the intelligent fire emergency lighting system is designedeffectively, scientifically and reasonably, so as to berter play the role of the system, effectively guide the crowd to evacuate in time in case of fire, so as toreduce people's life and property losses to the greatest extent, and the application of the system in the electrical design of civil buildings is discussed Theresearch will lay a solid foundation for improving the electrical design ofintelligent fire emergency lighting system in civil buildings
[ Keywords]
intelligent fire emergency lighting system; c/vil buildings; electrical design
在民用電氣設(shè)計過程中,消防應(yīng)急照明系統(tǒng)的設(shè)計非常重要,為了解決目前工程中普遍使用的消防應(yīng)急照明和疏散指示系統(tǒng)疏散指示方向固定,一旦有火災(zāi)發(fā)生,不能有序地引導(dǎo)人員迅速逃離火場,不能對該系統(tǒng)、燈具的運行及故障進行監(jiān)控等弊端,就需要做好民用建筑智能消防應(yīng)急照明系統(tǒng)的電氣設(shè)計及應(yīng)用分析,保障消防應(yīng)急照明系統(tǒng)安全可靠性,確保火災(zāi)事故時能引導(dǎo)人們高效有序地安全疏散,減少人身及財產(chǎn)損失,以提高人們對整個民用建筑的滿意度。
智能消防應(yīng)急照明系統(tǒng)是建筑電氣系統(tǒng)中的重要組成,是應(yīng)用在建筑火災(zāi)事故時人員疏散和逃生路線指示中的電氣系統(tǒng)。這就應(yīng)保證該項系統(tǒng)與建筑物中電氣系統(tǒng)運行的契合度和一致性,強化相關(guān)系統(tǒng)作用效果.避免智能消防應(yīng)急照明系統(tǒng)在實際應(yīng)用過程中受到阻礙,同時還應(yīng)保證系統(tǒng)中基礎(chǔ)零部件運行效果和現(xiàn)實作用。針對智能消防應(yīng)急照明系統(tǒng)展開研究,明確智能消防應(yīng)急照明系統(tǒng)是由光流子母燈、可調(diào)向疏散指示標(biāo)志燈、安全出口燈、區(qū)域_:集器、集中控制應(yīng)急燈主機、火災(zāi)探測器等基礎(chǔ)零部件組成的,這就應(yīng)保證各個零部件之間配合效果和關(guān)聯(lián)性,并在各個基礎(chǔ)軟件聯(lián)動配合條件下實現(xiàn)智能消防應(yīng)急照明系統(tǒng)穩(wěn)定運行狀態(tài),降低智能消防應(yīng)急照明系統(tǒng)在實際運行過程中出現(xiàn)各項問題的可能性,從而強化建筑物整體火災(zāi)防范效果,繼而將智能消防應(yīng)急照明系統(tǒng)在民用建筑中的現(xiàn)實作用和建筑物整體安全管控效果提升到一定高度。圖1為智能消防應(yīng)急照明系統(tǒng)示意圖。
智能消防應(yīng)急照明系統(tǒng)的功能表現(xiàn)在以下三個方面:①系統(tǒng)中智能化軟針對建筑物內(nèi)任意位置均有疏散預(yù)案,在火災(zāi)時立即點亮應(yīng)急照明燈,根據(jù)著火位置,自動形成最佳疏散路徑,標(biāo)志燈均按最佳路徑指示疏散方向,為人員消防出逃提供準(zhǔn)確路線支持。②智能消防應(yīng)急照明系統(tǒng)可以實現(xiàn)安全電壓供電的目標(biāo),這就可以保障消防員自身安全,避免消防員在慌亂中出現(xiàn)觸電事故,為民用建筑火災(zāi)消防處理提供有力支持。③智能消防應(yīng)急照明系統(tǒng)可以自動檢測實際運行過程中出現(xiàn)的故障問題,所有燈具都有獨立地址編碼,完全自動查詢燈具的好壞,故障時系統(tǒng)有故障提示,便于及時檢修,控制器可對系統(tǒng)內(nèi)部的所有組件工作狀態(tài)進行24h監(jiān)控,實時檢測其工作狀態(tài),保障智能消防應(yīng)急照明系統(tǒng)運行的安全性和穩(wěn)定性,確保民用建筑消防安全管理對其電氣設(shè)備以及相關(guān)系統(tǒng)設(shè)計所提要求落到實處。
在進行智能消防府急照明系統(tǒng)的電氣設(shè)計時需要考慮的要求比較多,具體如下:①應(yīng)對民用建筑中不同型號的智能消防應(yīng)急照明系統(tǒng)運行模式和作用效果展開研究,同時結(jié)合民用建筑整體規(guī)模形態(tài)確定電氣設(shè)計模式,保證民用建筑電氣設(shè)計效果,以此提升智能消防應(yīng)急照明系統(tǒng)在民用建筑中的運行效果和安全水下。同時還應(yīng)保證智能消防應(yīng)急照明系統(tǒng)與民用建筑中火災(zāi)自動報警系統(tǒng)等電氣設(shè)備之間配合力度,使得智能消防應(yīng)急照明系統(tǒng)在民用建筑中達到穩(wěn)定運行狀態(tài)。②應(yīng)充分了解相關(guān)民用建筑的特點、疏散通道及其它消防設(shè)施的設(shè)置情況,合理布置消防應(yīng)急照明疏散燈具、電源、應(yīng)急照明控制器等設(shè)施,并進行管線敷設(shè),選擇安全可靠、經(jīng)濟適用的智能消防應(yīng)急照明系統(tǒng),針對人樓內(nèi)各火情位置,反復(fù)比對設(shè)計的疏散路線是否為最佳的安全逃生路線,分析其實際運行效果,同時遵循基礎(chǔ)要求開展智能消防府急照明系統(tǒng)電氣設(shè)計,確保智能消防應(yīng)急照明系統(tǒng)電氣設(shè)計與其他相關(guān)電氣系統(tǒng)達到相互契合狀態(tài)。③應(yīng)對參與民用建筑智能消防應(yīng)急照明系統(tǒng)電氣設(shè)計的設(shè)計人員進行有效培訓(xùn),認(rèn)真學(xué)習(xí)和理解現(xiàn)行的消防及電氣設(shè)計規(guī)范,確保設(shè)計人員可以按照消防電氣設(shè)計規(guī)范、標(biāo)準(zhǔn)等開展民用建筑智能消防應(yīng)急照明系統(tǒng)電氣設(shè)計工作,同時開發(fā)和選用先進的專業(yè)CAD設(shè)計軟件,降低智能消防府急照明系統(tǒng)電氣設(shè)計難度,加強系統(tǒng)設(shè)計和應(yīng)用管理,提高設(shè)計效率。
為加人智能消防應(yīng)急照明系統(tǒng)在民用建筑電氣設(shè)計中的應(yīng)用力度,應(yīng)根據(jù)相關(guān)設(shè)計規(guī)范要求對民用建筑中智能消防應(yīng)急照明系統(tǒng)展開有效設(shè)計,保證其智能化系統(tǒng)運行效果和對民用建筑火災(zāi)信息的收集力度,并在全而收集民用建筑火災(zāi)信息的條件下維持其運行效果,保證智能消防應(yīng)急照明系統(tǒng)在民用建筑中發(fā)揮最人作用,保證民用建筑消防安全與應(yīng)急照明之間結(jié)合力度,同時強化光照傳感技術(shù)、溫度控制芯片技術(shù)和物聯(lián)網(wǎng)技術(shù)在其中應(yīng)用力度,提高該項電氣系統(tǒng)自動化水下,并在民用建筑發(fā)生火災(zāi)事故之后,及時為人們規(guī)劃安全疏散路線,確?;馂?zāi)現(xiàn)場人員可以在智能消防應(yīng)急照明系統(tǒng)指引下安全撤離,將智能消防應(yīng)急照明系統(tǒng)在民用建筑電氣設(shè)計中的應(yīng)用價值全面表現(xiàn)出來。
合理的供電線路設(shè)計才能使應(yīng)急電源供電時的持續(xù)工作時間符合消防設(shè)計規(guī)范相關(guān)要求,保證發(fā)生火災(zāi)事故時智能消防府急照明系統(tǒng)的連續(xù)、穩(wěn)定運行,確保供電線路設(shè)計可以滿足民用建筑中智能消防應(yīng)急照明系統(tǒng)良性運行要求。智能消防應(yīng)急照明系統(tǒng)的配電線路及通信線路均應(yīng)選擇耐火線纜應(yīng)穿金屬管保護暗敷在不燃燒體結(jié)構(gòu)內(nèi),且保護層厚度不少于30 mm,明敷時,應(yīng)采用耐火導(dǎo)線穿有防火保護的金屬管或有防火保護的封閉式金屬線槽,穿鋼管及電纜橋架、線槽明敷的那一段,其外壁應(yīng)涂防火涂料,確保供電線蹄安全可靠運行,為智能消防應(yīng)急照明系統(tǒng)穩(wěn)定運行提供電力支持。
智能消防應(yīng)急照明系統(tǒng)需要具備有效獨立的供電的裝置,由專用的消防應(yīng)急照明配電箱或廊急照明集中電源配電,應(yīng)結(jié)合各項基礎(chǔ)要求對智能消防應(yīng)急照明系統(tǒng)進行專業(yè)回路設(shè)計,同時要從根本上確保系統(tǒng)在一定程度上的消防應(yīng)急疏散照明時間,保證人群安全迅速疏散。封閉樓梯間、防煙樓梯間、室外疏散樓梯、避難層和避難層連接的下行樓梯間應(yīng)單獨設(shè)置配電回路。當(dāng)燈具采用集中電源供電時,燈具的主電源和蓄電池電源應(yīng)由集中電源提供,燈具主電源和蓄電池電源在集中電源內(nèi)部實現(xiàn)輸出轉(zhuǎn)換后應(yīng)由同一配電回路為燈具供電;當(dāng)燈具采用自帶蓄電池供電時,燈具的土電源應(yīng)通過府急照明配電箱為燈具供電,當(dāng)發(fā)生火災(zāi)事故時應(yīng)切斷主電源,自動轉(zhuǎn)入自帶蓄電池供電。另外,還府在系統(tǒng)末端連接自動化切換裝置以及相關(guān)控制系統(tǒng),保障智能消防應(yīng)急照明系統(tǒng)可以在長時間運行過程中自動切換蓄電池設(shè)備,保證民用建筑電氣設(shè)計效果和智能消防應(yīng)急照明系統(tǒng)運行的連貫性。
燈具作為智能消防應(yīng)急照明系統(tǒng)重要組成部分,對強化智能消防應(yīng)急照明系統(tǒng)的綜合運行效果至關(guān)重要。標(biāo)志燈應(yīng)選擇持續(xù)型燈具,要有疏散的標(biāo)志,正確地指引民眾找到最佳逃生方向。對燈具的容量選擇也要重視,智能消防應(yīng)急照明燈的設(shè)置應(yīng)保證為人員在疏散路徑及相關(guān)區(qū)域的疏散提供最基本的照度,智能消防應(yīng)急照明燈應(yīng)選擇具備瞬間點燃的熒光燈和LED高效節(jié)能光源,高危險場所燈具光源應(yīng)在0.25 s內(nèi)快速點亮,其他場所采用的燈具光源應(yīng)急點亮的響應(yīng)時間不應(yīng)人于5s。另外,還應(yīng)保證智能消防應(yīng)急照明系統(tǒng)燈具型材、亮度和基礎(chǔ)指引信號等方面達到合理狀態(tài),更好地滿足了民用建筑中智能消防應(yīng)急照明系統(tǒng)綜合設(shè)計要求。
智能消防應(yīng)急照明系統(tǒng)土機是該系統(tǒng)的核心控制部件,其主要功能是接收火災(zāi)報警系統(tǒng)發(fā)送的系統(tǒng)應(yīng)急啟動觸發(fā)信號,按預(yù)設(shè)邏輯自動控制系統(tǒng)的應(yīng)急啟動,實時顯示系統(tǒng)內(nèi)所有燈具、應(yīng)急照明集中電源或應(yīng)急照明配電箱等系統(tǒng)部件的工作狀態(tài),同時集中電源或應(yīng)急照明配電箱采用通信回路與其配接的燈具通信。因此,要想使智能消防應(yīng)急照明系統(tǒng)發(fā)揮最人的作用,保證報警機制與應(yīng)急照明機制之間聯(lián)動效果,確保智能消防應(yīng)急照明系統(tǒng)內(nèi)部各設(shè)備之間通信安全暢通,就必須要發(fā)計應(yīng)用與之相為匹配的通信系統(tǒng),在進行通信系統(tǒng)設(shè)計時,通信線路應(yīng)選擇耐火線纜或耐火光纖,同一工程中相同用途電線電纜的顏色應(yīng)一致。集中電源或應(yīng)急照明配電箱應(yīng)按燈具配電回路設(shè)置燈具通信回路,且燈具配電回路和燈具通信回路配接的燈具應(yīng)一致。同時還要選擇最為合理的通信技術(shù),確保通信質(zhì)量和效果,從而保障民用建筑的安全,提高了智能消防應(yīng)急照明系統(tǒng)應(yīng)用的質(zhì)量。
為提高智能消防應(yīng)急照明系統(tǒng)在民用建筑中的應(yīng)用力度,不僅需要將智能消防應(yīng)急照明系統(tǒng)的功能全而表現(xiàn)出來,還應(yīng)結(jié)合民用建筑空間功能和整體規(guī)劃要求進行電氣設(shè)計,保證智能消防應(yīng)急照明系統(tǒng)與民用建筑之間契合度,使智能消防應(yīng)急照明系統(tǒng)真正成為火災(zāi)逃生的指揮員,滿足人們對智能消防應(yīng)急照明系統(tǒng)電氣設(shè)計提出的要求。同時需要加強智能化手段的運用,更加有效且人性化地設(shè)計消防疏散應(yīng)急照明系統(tǒng),從而擴人智能消防府急照明系統(tǒng)在民用建筑中應(yīng)用范圍。
參考文獻
[1]鄭光照智能消防應(yīng)急照明系統(tǒng)在民用建筑電氣設(shè)計中的應(yīng)用[J]建筑與預(yù)算,2020 (10):73-75.
[2]徐冉民用建筑電氣設(shè)計中智能消防應(yīng)急照明系統(tǒng)的應(yīng)用[J].中國建筑金屬結(jié)構(gòu),2020 (10):66-67.
[3]鄧朝明.智能消防應(yīng)急照明系統(tǒng)在民用建筑電氣設(shè)計中的應(yīng)用研究[J]居舍,2019 (19):153.
[4]史雅娟民用建筑黽氣設(shè)計中智能消防應(yīng)急照明系統(tǒng)的應(yīng)用分析[J]建材與裝飾,2018 (2):71-72.
[5]陳淵民用建筑電氣設(shè)計中智能消防應(yīng)急照明系統(tǒng)應(yīng)用[J].低碳世界,2019 (6):133-134