      99热精品在线国产_美女午夜性视频免费_国产精品国产高清国产av_av欧美777_自拍偷自拍亚洲精品老妇_亚洲熟女精品中文字幕_www日本黄色视频网_国产精品野战在线观看 ?

      Safety and performance of the EverProTM everolimus-eluting coronary stent system with biodegradable polymer in a real-world scenario

      2021-01-08 08:01:50RahulTrimukhePreetiVaniArvindPatelVikasSalgotra
      World Journal of Cardiology 2020年12期

      Rahul Trimukhe,Preeti Vani,Arvind Patel,Vikas Salgotra

      Abstract BACKGROUND The EverProTM (Sahajanand Laser Technology Ltd.,India) everolimus-eluting coronary stent system (EES) is a second-generation drug-eluting stent with a biodegradable polymer. AIM To determine the safety and performance of the EverProTM EES in patients with coronary artery disease (CAD) during a 1-year clinical follow-up. METHODS This observational,retrospective,single-center study enrolled patients who had been implanted with the EverProTM stent between June 1,2018 and January 31,2019,and had completed a 1-year follow-up period after the index procedure.The primary clinical endpoint was major adverse cardiac events (MACE) at 6 mo defined as the composite of cardiac death,myocardial infarction (MI),and target lesion revascularization (TLR).Secondary endpoints were the incidence of TLR at 1,6 and 12 mo follow-up,MACE at 1 and 12 mo follow-up,and stent thrombosis up to 1 year after the index procedure. RESULTS The study population comprised 77 patients (98 lesions).A total of 37 (48.1%)patients had comorbid hypertension.In total,26 (33.8%) patients presented with ST segment elevation MI and 10.4% patients with non-ST segment elevation MI.Treated lesions were located mainly in the left anterior descending artery (49%)followed by the right coronary artery (29.6%),left circumflex (12.2%) and obtuse marginal (9.2%) arteries.The majority of patients were with single-vessel disease(79%),22.2% of lesions had a mild to severe thrombus load,and 94.9% were American College of Cardiology/American Heart Association type B or C.De novo stenting was performed in 96.9% of patients and 3% were treated for in-stent restenosis.Procedural success was attained in all patients.In-hospital or followup MACE and stent thrombosis were not reported during the 1-year follow-up period. CONCLUSION These findings suggest that the EverProTM EES is a safe and effective treatment option with no MACE or stent thrombosis reported during the 1-year study period in patients with CAD.

      Key Words:Coronary artery disease;Everolimus;Major adverse cardiac event;Retrospective,EverProTM,Myocardial infarction

      INTRODUCTION

      The incidence of coronary artery disease (CAD) has been increasing,causing significant morbidity and mortality worldwide[1].Percutaneous coronary intervention is an increasingly performed revascularization modality for the treatment of CAD.It aims to restore blood supply to myocardial tissues with poor blood supply due to coronary stenosis or vessel occlusion.

      Bare-metal stents (BMS) have demonstrated superior clinical outcomes over balloon angioplasty,but neointimal hyperplasia and restenosis are the major challenges in BMS technology.Evidence suggests that revascularization rates have markedly decreased with the use of drug-eluting stents (DES) compared to BMS[2-4],but the risk of late stent thrombosis was the major limitation of the first-generation of DES.Second-generation DES were designed to reduce stent thrombosis and maintain good acute and long-term results.Advances in DES technology,such as new polymers,novel platform material and structure,alteration in coating distribution or additional coating and better antiproliferative drugs,have resulted in the development of new generations of DES.

      Polymer composition and stent strut thickness are important factors affecting the clinical outcomes of DES.First-generation DES were manufactured from durable polymer and had thick struts which trigger the inflammatory process and induce stent thrombosis,while the new-generation DES employ biocompatible polymers that will be fully resorbed by hydrolysis after drug release.The strut thickness greatly differs among the available biodegradable polymer DES and thinner struts reduce vessel wall injury,decrease inflammation and promote faster endothelialization[5].The strut thickness of new-generation biodegradable polymer stents is half of that in the firstgeneration biodegradable polymer DES[6].Therefore,new-generation DES reduce the risk of stent thrombosis compared with first-generation DES,particularly very late stent thrombosis that can occur after discontinuation of dual antiplatelet agents[4].Coronary stent systems with metal alloys and biodegradable polymers show similar clinical outcomes compared with durable polymer DES[7-9].

      Antiproliferative drugs in the second-generation DES belong to the “l(fā)imus family”(sirolimus,everolimus,zotarolimus) that inhibit mammalian target of rapamycin,and everolimus is known to exert much higher interaction with rapamycin complex 2.This interaction blocks protein synthesis and arrests cell cycle progression,inhibits smooth muscle cell proliferation and reduces stent restenosis.Everolimus has higher bioavailability and a shorter half-life than sirolimus;it decreases vascular inflammation and promotes rapid endothelialization.Everolimus-eluting stents have outperformed paclitaxel DES,and outcomes are comparable with zotarolimus- and sirolimus-eluting stents in terms of safety and efficacy as shown in various clinical studies[10-12].The EverProTMeverolimus-eluting coronary stent system (EES) is an approved coronary stent system with a biodegradable polymer.It has an ultra-thin (60 μm) cobaltchromium platform design that facilitates a reduction in intra-arterial injury.The present post-marketing surveillance study aimed to determine the safety and performance of the EverProTMEES in patients with CAD during the 1-year clinical follow-up.

      MATERIALS AND METHODS

      Study design

      In this single-center,observational study,consecutive patients who were implanted with the EverProTMstent between June 1,2018 and January 31,2019 at The Atma Malik Hospital,Maharashtra,India,and who completed 1-year follow-up were retrospectively selected from June 2019 to January 2020.The study protocol was approved by an independent ethics committee (Sangini Hospital Ethics Committee on June 8,2020),and a waiver of informed consent was obtained.The study was conducted in accordance with the Declaration of Helsinki and the principles of good clinical practice,CTRI/2020/07/026564.

      Patient selection

      All patients aged >18 years and implanted with EverProTMstents to treat CAD were included.Patients treated with stents other than the EverProTMstent during the index procedure,pregnant/lactating women,and those with grade III renal insufficiency,left ventricular ejection fraction <30%,history of cardiac failure,structural heart disease,cardiomyopathies,or arrhythmia were excluded.A detailed description of the inclusion and exclusion criteria is provided in Figure 1.

      Device description

      The EverProTM(Sahajanand Laser Technologies Ltd.,India) EES is an approved DES comprising a biodegradable polymer and surgical grade cobalt-chromium L605 alloy,everolimus as the active pharmaceutical ingredient and poly-l-lactide (PLLA) and poly-dl-lactide-co-glycolide (PLGA) as the drug carrier.PLLA and PLGA in the EverProTMEES slowly and gradually erode within six months into small molecules,and are metabolized and excreted as carbon dioxide and water.The design of the everolimus-eluting coronary stent is an 8-crown laser cut hybrid design that provides uniform vessel scaffolding and drug distribution (Figure 2).

      Study procedure and data collection

      The indications for the angioplasty procedure and stent implantation were at the discretion of the treating physicians per the standard treatment guidelines.Baseline patient data,including age,gender,medical history,angina status,and clinical presentation were collected retrospectively from inpatient and outpatient clinical notes,angiogram reports,and procedural angiographic images and discharge summaries.Routine laboratory data including cardiac biomarkers,blood chemistry,and 12-lead electrocardiogram were also collected.The data from the paper case report forms were translated to a central database that was used for the final analysis.The follow-up data of patients attending the clinic were extracted from their medical records.A few patients were followed up by telephone and asked a list of questions from a structured questionnaire to determine the exact status of the endpoint.We excluded patients with incomplete medical notes or those who did not respond to telephonic follow-ups.

      Figure 1 Eligibility criteria for the study.

      Study endpoints and definitions

      The primary clinical endpoint of this study was major adverse cardiac events (MACE)at 6-mo follow-up.MACE was defined as a composite of cardiac death,myocardial infarction (MI),and target lesion revascularization (TLR).The secondary endpoints consisted of TLR at 1,6 and 12 mo follow-up,MACE at 1,and 12 mo follow-up,and the frequency of stent thrombosis up to 1 year after the date of stent implantation.The outcomes of stent thrombosis were further divided into definite,probable,and possible stent thrombosis,as defined by The Academic Research Consortium[13,14].Cardiac death was considered in the case of any death owing to cardiac cause (MI,low output failure and lethal arrhythmia),unobserved death,death due to unknown reasons,and all procedure-related deaths,including those associated with concomitant treatment.MI was defined as an increase in cardiac troponin values [>5 × 99thpercentile upper reference limit (URL)] in patients with normal baseline values (≤ 99th percentile URL) or an increase in cardiac troponin values of >20% when the baseline values were elevated and stable,or declining.Pathological Q waves were defined as per amplitude,location,and depth if they were present in at least two contiguous leads.Restenosis within the stent or in the 5-mm distal or proximal to the stent was considered to require TLR.Stenosis in any segment of the treated vessel was defined as target vessel revascularization.The incidence of stent thrombosis was considered acute if it occurred within 24 h,sub-acute if it occurred between 1 and 30 d,and late if it took place after 30 d.Any symptoms suggestive of an acute coronary syndrome and angiographic or pathological confirmation were termed as definite stent thrombosis.Any unexplained death within 30 d or target vessel MI without angiographic confirmation of stent thrombosis was described as probable stent thrombosis.Unexplained death after 30 d was described as possible stent thrombosis.

      Figure 2 Design of the everolimus-eluting coronary stent.

      Statistical analysis

      All calculations were based on the available data and missing data were excluded from the calculations.Categorical data are presented as frequency and percentages.Continuous variables are presented as the mean ± standard deviation (SD).The data were analyzed using the Statistical Package for Social Sciences program (SPSS Inc.,Chicago,IL,United States),version 23.

      As no hypothesis was tested in the study,we did not perform formal sample size calculation and included patients who met the eligibility criteria during the stipulated time.

      RESULTS

      Baseline demographic and clinical characteristics

      The total study population comprised 77 patients (98 lesions).Baseline demographic and clinical characteristics are shown in Table 1.The mean (SD) age of patients was 55± 11.8 years,and 77% were men.A total of 48% of patients had comorbid hypertension,19.4% had diabetes,and 31% were smokers.The majority of patients presented with MI (44.2%) followed by stable angina in 39%.The majority of patients had single-vessel disease (79%).

      Procedural and lesion characteristics

      A total of 102 lesions were detected in these patients,and 98 lesions were treated by implantation of the EverProTMstent.Treated lesions were located mainly in the left anterior descending artery (49%),followed by the right coronary artery (29.6%),left circumflex (12.2%) and obtuse marginal (9.2%) arteries.Approximately 22.2% of lesions had a mild to severe thrombus load and 94.9% lesions were American College of Cardiology/American Heart Association type B or C.De novostenting was performed in 96.9% of patients and 3% were treated for in-stent restenosis.Procedurerelated details are shown in Table 2.Procedural success was attained in all patients with no in-hospital MACE.All patients were prescribed antiplatelet agents at discharge (Table 2).

      Table 1 Baseline demographics and clinical characteristics

      Clinical outcomes during follow-up

      MACE and stent thrombosis were not observed in any patient throughout the 1-year follow-up period.

      DISCUSSION

      This post-marketing surveillance study was performed to determine the safety and performance of EverProTMstents for the treatment of CAD in a real-world clinical setting.The results of this study show that the EverProTMstent was not associated with MACE or TLR.In addition,stent thrombosis was not observed during the 1-year follow-up period.

      The clinical performance and safety of everolimus-eluting stents in the treatment of CAD have been well documented.The series of SPIRIT clinical trials demonstrated the superior efficacy of EES over BMS and paclitaxel-eluting stents[10].Furthermore,a meta-analysis of the final results of SPIRIT II,III,and IV clinical trials demonstrated that EES was superior to paclitaxel-eluting stents in reducing target lesion failure (8.9%vs12.5%,P=0.0002),all-cause mortality (3.2%vs5.1%,P=0.003),MI (3.2%vs5.1%,P=0.002),cardiac death or MI (4.4%vs6.3%,P=0.005),ischemia-driven TLR (6.0%vs8.2%,P=0.004),stent thrombosis (0.7%vs1.7%,P=0.003),and MACE (9.4%vs13.0%,P=0.0002)[11].The safety and efficacy of EES have also been demonstrated in selected high-risk patients in real-world studies.The XIENCE V United States trial evaluated 5054 participants,and 98.1% reached the 1-year follow-up.No stent thrombosis was observed in standard-risk and high-risk patients even after discontinuation of dual antiplatelet therapy after 6 mo[15].EES have been compared with sirolimus-eluting stents,and at 5 years,MACE (14.0%vs17.4%,respectively) and stent thrombosis (0.4%vs2.0%,respectively) rates were found to be lower in the EES group than in the SES group[16].Clinical studies comparing zotarolimus-eluting stents (ZES) to EES have shown that ZES are non-inferior to EES with regard to death from cardiac causes,MI,or clinically indicated TLR within 1 year.However,the rate of stent thrombosis was higher with ZES than with EES (2.3%vs1.5%)[17].In a meta-analysis,compared to paclitaxel and sirolimus,EES were also found to be more efficacious and safe in patients with concomitant diabetes,resulting in a reduction in MACE by 18%,MI by 43%,and stent thrombosis by 46%[18].

      Table 2 Procedural and lesion characteristics

      The 12-mo MACE rate following implantation of EES ranged from 0.3% to 6.2% for diverse clinical presentations in randomized trials,and real-world studies[19-24].The 1-year incidence of MACE following treatment with another indigenous biodegradable polymer DEC ranged from 0.9% to 4.2%[25-27].No MACE was reported during the 1-year follow-up period in our study.The EverProTMstent has a very thin strut (60 μm)and it is built on a cobalt-chromium L605 alloy platform with SCHIFSORB polymer technology.The biodegradable polymers PLLA and PLGA degrade entirely and reduce the risk of thrombosis.The stent has an innovative “S”- and alternate “C”-linked 8-crown design that enhances flexibility and provides high radial strength.With foreshortening of <0.2%,it is ideal for all lesion locations,including ostial lesions.Additionally,the utilization of electropolishing technology results in an ultrasmooth stent surface that reduces the risk of edge dissection and very late stent thrombosis.These properties may have contributed to the procedural success and good clinical outcomes observed in this study.

      While these data on the use of the EverProTMstent in the treatment of CAD are very promising,this study is limited by its observational design,retrospective analysis of data,small sample size,and a short follow-up period.Therefore,the results need to be substantiated in well-designed studies with a longer follow-up duration.

      CONCLUSION

      The findings of this study support the favorable safety and performance of the EverProTMEES.Product characteristics,such as the conformal coating of everolimus and ultra-smooth stent surface,which provides high radial strength with minimal foreshortening,may be responsible for the results.The EverProTMEES could be an effective alternative to other contemporary DES for the treatment of CAD.

      ARTICLE HIGHLIGHTS

      Research background

      The increasing prevalence of coronary artery disease (CAD) has caused significantly higher rates of morbidity and mortality worldwide.Thus,percutaneous coronary intervention,a revascularization modality to treat CAD,restores blood supply to myocardial tissues.Antiproliferative drugs in second-generation drug-eluting stents(DES) inhibit mammalian target of rapamycin and affect stent restenosis.However,EverProTM,an approved second-generation everolimus-eluting coronary stent system(EES) with a biodegradable polymer facilitates a reduction in intra-arterial injury.

      Research motivation

      Sirolimus has a longer half-life,lower bioavailability and does not directly affect stent restenosis.However,everolimus outperforms sirolimus and can decrease vascular inflammation and promote rapid endothelialization.These findings indicate the potential of EES to replace second-generation DES and impart benefits to patients with CAD.

      Research objectives

      The objectives of this study were to determine the safety and performance of EverProTMEES in a real-world scenario and to translate its use in the real world as an effective alternative to DES for the treatment of CAD.The EverProTMEES could offer various benefits in addition to reduced stent restenosis and rapid endothelialization.

      Research methods

      This single-center,observational study enrolled patients who completed a 1-year follow-up period after being implanted with the EverProTMstent (between June 1,2018 and January 31,2019).As no hypothesis was tested in the study,we did not perform a formal sample size calculation and included patients who met the eligibility criteria during the stipulated time.

      Research results

      Of the 102 lesions detected in the included patients,98 lesions were treated by implantation of the EverProTMstent.De novostenting was performed in 96.9% of patients and 3% were treated for in-stent restenosis.Procedural success was attained in all patients with no in-hospital major adverse cardiac events (MACE) or stent thrombosis observed throughout the follow-up period.However,the results were limited by the study’s observational nature,retrospective data analysis and a shorter follow-up period.

      Research conclusions

      The results showed that EverProTMEES is a safe and effective treatment alternative as no MACE or stent thrombosis was observed during the 1-year study period in patients with CAD.

      Research perspectives

      The data on the use of the EverProTMstent in the treatment of CAD are very promising.However,if future studies can overcome the study limitation by conducting welldesigned studies with a larger sample size and a longer follow-up duration,EverProTMEES can be used as an alternative to contemporary DES for treating CAD.