【摘 要】為了摸清管道運(yùn)輸公司18條油氣管道陰極保護(hù)系統(tǒng)目前的運(yùn)行現(xiàn)狀及存在的問(wèn)題,為今后油氣管道的陰極保護(hù)設(shè)計(jì)、施工、管理打好基礎(chǔ),近期,筆者先后對(duì)6個(gè)分公司及其存在問(wèn)題的場(chǎng)站、線(xiàn)路進(jìn)行了調(diào)研、抽查測(cè)試,了解了管道運(yùn)輸公司油氣管道陰極保護(hù)運(yùn)行現(xiàn)狀,發(fā)現(xiàn)管道陰極保護(hù)系統(tǒng)相關(guān)問(wèn)題共36個(gè),針對(duì)這些問(wèn)題,筆者給出了解決意見(jiàn)或建議。
【Abstract】 In order to find out the current situation and problems of the cathodic protection system of 18 oil and gas pipelines in the pipeline transportation company, and lay a good foundation for the cathodic protection design, construction and management of oil and gas pipelines in the future . Recently, the author has carried on the investigation and the spot check test to the 6 branches as well as the station and the line with problems.The present situation of cathodic protection operation of oil and gas pipeline in pipeline transportation company is studied.It is found that there are 36 problems in cathodic protection system. For these issues, the author gives suggestions.
【關(guān)鍵詞】油氣管道;陰極保護(hù);運(yùn)行現(xiàn)狀
【Keywords】oil and gas pipeline; cathodic protection; operation status
【中圖分類(lèi)號(hào)】TE988 【文獻(xiàn)標(biāo)志碼】A 【文章編號(hào)】1673-1069(2017)04-0156-02
1 調(diào)研排查地點(diǎn)
第一次:2016年11月29日至12月10日,先后到輸油第二分公司及其安永線(xiàn)路2處測(cè)試樁、陽(yáng)極樁;輸油第三分公司及其巡線(xiàn)隊(duì)一隊(duì)、楊姚線(xiàn)2處測(cè)試樁、姚店聯(lián)合站;輸氣第一分公司;輸油第四分公司及其吳延線(xiàn)的野山站、野山站附近管線(xiàn);輸油第一分公司及其靖榆線(xiàn)的靖榆聯(lián)合站、小河天賜灣-靖邊線(xiàn)喬溝灣站;輸油第五分公司及其延西線(xiàn)的惠家河首站、銅川清管站、臨潼末站。
第二次:2017年1月17日至25日,先后到輸油第二分公司線(xiàn)路、閥室等6處,輸氣第一分公司閥室、線(xiàn)路等6處,輸油第三分公司線(xiàn)路5處,輸油第一分公司線(xiàn)路、閥室、場(chǎng)站21處,輸油第四分公司線(xiàn)路、場(chǎng)站30處,輸油第五分公司線(xiàn)路8處進(jìn)行抽測(cè)保護(hù)電位。
2 存在問(wèn)題
2.1 共性問(wèn)題
①公司陰極保護(hù)原設(shè)計(jì)、原施工、整改遺留問(wèn)題較多,比如,測(cè)試樁、犧牲陽(yáng)極、輔助陽(yáng)極等處存在設(shè)計(jì)標(biāo)準(zhǔn)過(guò)舊、考慮不全,施工偷工減料、監(jiān)管與驗(yàn)收不嚴(yán)格等現(xiàn)象,導(dǎo)致陰極保護(hù)效果差,銹蝕嚴(yán)重。[1]
②以前整改過(guò)的陰極保護(hù)問(wèn)題現(xiàn)在又成了新問(wèn)題,如線(xiàn)路增加犧牲陽(yáng)極、排流器等處。
③陰極保護(hù)測(cè)試設(shè)備單一,類(lèi)型少,部分設(shè)備用舊或用壞,有的在維修、維護(hù)中。
④陰極保護(hù)管理人員、技術(shù)人員流動(dòng)變化快,多數(shù)不愿干數(shù)字、數(shù)據(jù)多的技術(shù)工作,公司整體缺少陰極保護(hù)管理人員和技術(shù)人員,管道陰極保護(hù)管理、技術(shù)力量很薄弱。
⑤線(xiàn)路土壤環(huán)境、氣候環(huán)境不同,存在保護(hù)電位偏低、偏高、測(cè)不準(zhǔn)等異?,F(xiàn)象。
2.2 個(gè)性問(wèn)題
輸油第一分公司。①靖榆原線(xiàn)后半段測(cè)試樁陰極保護(hù)電位偏高。②陰極保護(hù)檢測(cè)設(shè)備單一,種類(lèi)少,不能滿(mǎn)足現(xiàn)在工作需要。③每條管線(xiàn)前期設(shè)計(jì)、建設(shè)遺留問(wèn)題多,如絕緣接頭、陽(yáng)極、匯流點(diǎn)都沒(méi)有專(zhuān)用測(cè)試樁。④樊學(xué)—東仁溝管線(xiàn),東仁溝站西南2km附近65號(hào)測(cè)試樁,保護(hù)電位,-0.692V,偏低,異常。⑤定靖原線(xiàn)93號(hào)標(biāo)高樁附近的測(cè)試樁,保護(hù)電位,-1.421V,偏高,異常。⑥喬溝—靖邊管線(xiàn)23號(hào)測(cè)試樁,保護(hù)電位測(cè)不準(zhǔn)(草坪、凍層)。⑦靖榆原線(xiàn),2號(hào)測(cè)試樁,保護(hù)電位,-1.326V,偏高,異常。
輸油第二分公司。①陰極保護(hù)技術(shù)員人缺少。②管道陰極保護(hù)系統(tǒng)以前改造增加犧牲陽(yáng)極的地方,現(xiàn)在全部成為防腐隱患檢測(cè)漏點(diǎn)。③安永線(xiàn)17號(hào)測(cè)試樁,保護(hù)電位,-0.780V,偏低,異常。④安永線(xiàn)井家坪至余家坪段,后滴哨8號(hào)測(cè)試樁,保護(hù)電位,-0.777V,偏低,異常;后滴哨9號(hào)測(cè)試樁,保護(hù)電位,-0.774V,偏低,異常;后滴哨閥室,保護(hù)電位-0.696V,偏低,異常。
輸油第三分公司。①姚店聯(lián)合站2臺(tái)恒電位儀輸出電流過(guò)低。②巡線(xiàn)隊(duì)缺少數(shù)據(jù)分析技術(shù)人員。③川口—姚店管線(xiàn),川口附近38號(hào)測(cè)試樁,保護(hù)電位,-0.693V,偏低,異常;川口附近40號(hào)測(cè)試樁,保護(hù)電位,-0.652V,偏低,異常。
輸油第四分公司。①野山輸油輔助陽(yáng)極地床的問(wèn)題,即陽(yáng)極地床接地
電阻過(guò)大,無(wú)法輸出足夠大的電流,在旱季接地電阻達(dá)到10Ω左右,雨季也在7Ω左右;在旱季通過(guò)注水能降低到7Ω左右,但過(guò)段時(shí)間接地電阻又變大。②徐莊支線(xiàn)、野山聯(lián)合站支線(xiàn)、宜西溝支線(xiàn)插入主管線(xiàn)的插入口無(wú)絕緣接頭導(dǎo)致巡護(hù)一隊(duì)線(xiàn)路欠保護(hù)問(wèn)題。③石百萬(wàn)聯(lián)合站—吳起站、關(guān)家溝聯(lián)合站—甘泉站、洛川末站—延安煉油廠(chǎng)三段管線(xiàn)無(wú)陰極保護(hù)問(wèn)題。④劉坪站附近1號(hào)測(cè)試樁,保護(hù)電位,-0.488V,偏低,異常。⑤劉坪站附近15號(hào)測(cè)試樁,保護(hù)電位,-0.625V,偏低,異常。⑥直羅-富縣段,53號(hào)測(cè)試樁,保護(hù)電位,-0.780V,偏低,異常。⑦富縣-直羅段,78號(hào)測(cè)試樁,保護(hù)電位,-0.370V,偏低,異常。
輸油第五分公司。①陰極保護(hù)技術(shù)力量薄弱,人員緊缺,巡線(xiàn)隊(duì)人員數(shù)據(jù)分析能力弱,大多是兼職技術(shù)員。②前期項(xiàng)目建設(shè)遺留問(wèn)題多,斷電點(diǎn)位、匯流點(diǎn)等處沒(méi)有預(yù)留測(cè)試樁和相關(guān)標(biāo)識(shí)。
天然氣第一分公司。①臨鎮(zhèn)—子長(zhǎng)干線(xiàn),姚店閥室外南3km處46號(hào)測(cè)試樁,保護(hù)電位測(cè)不準(zhǔn)。②姚店閥室—方橋清管站,楊家砭5號(hào)測(cè)試樁,康家溝7號(hào)測(cè)試樁,保護(hù)電位均測(cè)不準(zhǔn)。
3 結(jié)論與建議
①公司上下嚴(yán)把工程項(xiàng)目設(shè)計(jì)、施工、招標(biāo)、供貨、驗(yàn)收,杜絕管道儲(chǔ)罐底板陰極保護(hù)、測(cè)試樁、犧牲陽(yáng)極、輔助陽(yáng)極等處存在設(shè)計(jì)不足不全、施工偷工減料及監(jiān)管與驗(yàn)收不嚴(yán)格、陰極保護(hù)質(zhì)量效果差、銹蝕嚴(yán)重、標(biāo)識(shí)缺少、恒電位儀缺少標(biāo)識(shí)與數(shù)據(jù)不穩(wěn)定等類(lèi)似現(xiàn)象再次發(fā)生。
②各分公司對(duì)于整改的陰極保護(hù)項(xiàng)目,申報(bào)前一定充分論證、長(zhǎng)遠(yuǎn)考慮,不能是問(wèn)題就整改,只顧眼前,一個(gè)問(wèn)題整改了,卻埋下新問(wèn)題。
③各分公司采取激勵(lì)措施,盡量把陰極保護(hù)業(yè)務(wù)熟的人員留在陰極保護(hù)崗位,盡量配上專(zhuān)職技術(shù)人員,加強(qiáng)陰極保護(hù)技術(shù)人員理論與實(shí)踐培訓(xùn)學(xué)習(xí)。
④各分公司巡線(xiàn)隊(duì)技術(shù)人員對(duì)測(cè)試數(shù)據(jù)不準(zhǔn)的測(cè)試樁應(yīng)從測(cè)試方法、設(shè)備使用、設(shè)備問(wèn)題等方面查找測(cè)試不準(zhǔn)的原因,確保數(shù)據(jù)的真實(shí)性、有效性;對(duì)難點(diǎn)異常數(shù)據(jù)和技術(shù)問(wèn)題,逐級(jí)分析原因,逐級(jí)按照公司陰極保護(hù)及防腐管理辦法規(guī)定程序上報(bào),層層分析解決。
⑤各分公司經(jīng)常維護(hù)好測(cè)試、檢測(cè)等設(shè)備和工具,一旦發(fā)現(xiàn)異常要及時(shí)進(jìn)行維修、維護(hù)和校驗(yàn)。
⑥各分公司線(xiàn)路存在的個(gè)性問(wèn)題,組織技術(shù)力量近期前往現(xiàn)場(chǎng)再?gòu)?fù)查測(cè)試,對(duì)較為復(fù)雜的問(wèn)題,外請(qǐng)陰極保護(hù)專(zhuān)業(yè)技術(shù)隊(duì)伍拿出整改意見(jiàn)或方案。
⑦針對(duì)陰極保護(hù)難點(diǎn)“瓶頸”問(wèn)題,公司或分公司可列為優(yōu)秀課題進(jìn)行研究,也可請(qǐng)相關(guān)單位再進(jìn)行現(xiàn)場(chǎng)調(diào)研,拿出整改措施或整改方案,立項(xiàng)研究。
4 結(jié)語(yǔ)
通過(guò)本次對(duì)管道運(yùn)輸公司18條油氣管道線(xiàn)路、40多個(gè)輸油氣場(chǎng)站的82臺(tái)恒電位儀的調(diào)研、排查測(cè)試,發(fā)現(xiàn)公司前期工程項(xiàng)目設(shè)計(jì)、施工、監(jiān)管、驗(yàn)收、招標(biāo)、采購(gòu)、管理等環(huán)節(jié)存在很多漏洞和不足,導(dǎo)致現(xiàn)役管道陰極保護(hù)系統(tǒng)失效失靈、欠保護(hù)、過(guò)保護(hù)、雜散電流干擾嚴(yán)重等潛在隱患和問(wèn)題,引以為鑒,今后公司在對(duì)新建工程陰極保護(hù)系統(tǒng)方面,要嚴(yán)格管控陰極保護(hù)系統(tǒng)設(shè)計(jì)施工、監(jiān)管、驗(yàn)收、招標(biāo)、采購(gòu)等環(huán)節(jié)的質(zhì)量關(guān)和技術(shù)關(guān),避免類(lèi)似問(wèn)題出現(xiàn)。
【參考文獻(xiàn)】
【1】張明敏.吳起延煉原油管道陰極保護(hù)系統(tǒng)運(yùn)行及維護(hù)[D].西安:西安石油大學(xué),2013.